Bolted Flange Design - Changelog

Version: 0.0.23a - 29/12/2020

Below you'll find all the changes made in the Bolted Flange Design module, from the first version to the last (actual). If you have any question please visit the Documentation page or the Forum.

Version: 0.0.9a - 13/07/2020

Features Added
IDFeatureDescription
22Export calculation report to PDF or DOC fileInclude a button in the 'results page' which let the user export the calculation report to a PDF or DOC file. Almost done. If you wan't to have a preview just download it . Last step to finish: include the 'input' information from results page into the DOCX.
27Material list dropdown in the 'input page'As we created the 'Material Database' (ASME BPVC Section II) it's now possible to load the list in the material list dropdown.
28Show the 'input' values in the 'results' pageCreate a section in the 'results' page to show the 'input' values, so the user don't need to go back to 'input' page to check what values have been used. Put it before the equations/calculation.
29Show results using 'accordion' styleShow results using 'accordion' style just like in the 'input page', because there's too much information to be show to user so, to avoid having to scroll to the end of the page, which can take some time, it would be better using 'accordion', separating the results by section.
30Show 'Minimum Required Flange Thickness' in the 'input' pageShowing the 'Minimum Required Flange Thickness' in the 'input' page will help avoid going back and foward between 'input' and 'results' page as the user will know the minimum thickness needed before hitting 'calculate'.
31Include a 'Save Project' to database optionInclude a button in the 'input page' to save the information to database, so the user can use it latter.
36Create a method to auto generate the report numberAuto Generate Report Number is a checkbox field in the 'input page'. Create a method and implement it.
37Find a way to export svg/image to DOC and/or PDF filesSo far all modules will use SVG for image generator. As the images are dynamic generated according to user inputs, find a way to export it to calculation reports (can be to DOC or PDF).
38Check the need for 'modal window'Don't really know where should I use 'modal window'. In the past I would use so the user could have access to material database, but know I think it isn't needed anymore.
39Create a method to automatically update all pages regarding specific module.For example, if the version of module is updated, all page header from this module should be updated as well.
Bugs Fixed
IDBugDescription
3Gasket properties for 'elastomers' (first option from dropdown list) is not loadingThere was a problem with the database connection. The 'loadGasketProperties()' function was being fired before the gasket material list being fully loaded.
4Drawing from Figure 2-4(5) is all messed up (input values)When selecting the Fig. 2-4(5) and click 'calculate' the generated drawing in the 'results' page is all messed up.
17Check the inputs in the results page. It's taking the wrong value from selectIt's not taking the text from select. Instead, it's taking the value.

Version: 0.0.23a - 29/12/2020

Features Added
IDFeatureDescription
5Dynamic flange drawing in the 'input page'Change the flange drawing according to user input (flange inside diameter, flange outside diameter, etc)
61Include 'Documentation' and 'Version' button in the top of pageSuch buttons will help users clear identify where they can find more information about the module. Them it would be a good ideia to remove 'Documentation' link from menu and 'Version and Date' from bellow title.
63Create a dynamic page that shows the last (or all) version changes when clicking in the 'Version' buttonThe version button is in the module page together with the 'Documentation' button. I would be nice to be able to show the changes of versions. Need to be dynamic and not static, otherwise would need too much work. Should be used by all modules (and maybe pages).
Bugs Fixed
IDBugDescription
10Check if we can keep using the number cells as FLOAT or it may me better to change to DECIMALWhen comparing two floats, it's possible that even though it's the same number, they aren't equal. Example: float1 = 0.123 and float2 = 0.123, float1 != float2. Such a thing doesn't happens with DECIMAL. This settings (type of number) can easily be changed in the database (phpMyAdmin).
13Error when inserted temperature below 100CWhen the user insert temperature below 100C, lets say, 1C, the system can't find the yield stress.
14Lap information are being shown in the results page when it shouldn'tEven though the user didn't choose a lap flange, the information regarding this type of flange are being shown (example: lap outside diameter and lap flange thickness)
16Error of image not found in the results page.What's happening: the system may be calling the function to generate the DOCX more than one time. In the first time it generate the file (it's saved in the temp folder) and the second time it try to generate the file but can't find the image. Try to fix it as soon as possible to avoid to many images being saved in the server.
22Remove 'Lap Outside Diameter' and 'Lap Flange Thickness' (inputs) from results (output) page.Even though the flange selected wasn't a 'Lap Joint' type, the 'Lap' inputs appeared in the results (output) page. Remove it.
23All checkbox's appears as 'yes' in the results page (output) even though it wasn't checked.Check the code to see what is causing such behavior and fix it. Checkbox that appear in the results (output) page: 'useCorrosionAllowance', 'useB1InsteadofB0', 'flangeIsMaterialNormalized' and 'boltIsMaterialNormalized' (these are the 'code' name, not the name that appear in the results page).
24In the 'input' part of the results (output) page, the 'º' symbol doesn't appear before the 'C' or 'F'Check the code and, if needed, change the symbol for HTML/ASCII code.
25In the results (output) page, some equations are showing '&pi' instead of the pi symbol.It was found in the following equations: HP, Wm2 and beta (this one is showing pi() but still wrong).
26Some equations are outputting '$' (dollar symbol) in the equations. Remove it.The following equations are outputting it: hD, BSf, SRa and SRo.
27The input field 'Loose or Integral' is showing in the results (output) page even though the 'Flange Type' isn't 'Optional'.Other point the check is that the flange was an 'Integral' type and the 'Loose or Integral' field was showing it as 'Loose'.
28'Bolt Root Area', in the results (output) page are shown with 3 decimal places, check if it's really needed.Check it is being rounded in the equation file.
29Some 'td/>' is showing in the bolt 'Elastic Modulus' input in the results (output) page. Remove it.Try checking the equation file.
33Parentheses missing in the 'Am' and 'SHo' equation.Put the missing parentheses in the 'Am' and 'SHo' equations. Check the equation file.
34Missing '/2' in the 'Wg' equation in the results (output) page.Insert the missing '/2' in the 'Wg' equation, check equation/calculation file.
35Written 'Componente' instead of 'Component' in the 'MD' equation. Fix it.Just a typo. Check results file to fix it.
36No result are shown for the 'factorSube' in the results (output) page.Try looking in the equation file, it's something to do with the 'class' echoed in the equation.
38In the results (output) page, in the factors table, the 'Z' variable isn't in bold.Set the variable as 'bold' in the results file.
39'STa' equation is missing the title and the result.Check the results or equation file. Maybe there's an 'echo' missing.
40Result didn't shown for the 'alpha_sh' and 'mawp_hta'.It should have a result as the calculation steps was shown. Check equation file.
47Bolt diameter in drawing is different from the one shown in the 'Text Field' (not for every value)While selecting 2" UNC, although the value shown in the 'Bolt Nominal Diameter - BoltND' was 50.8, the drawing shown 15.875. Maybe something to do with the database search type (selected the first one that have "2" in it, like 1/2").